ConfigChannelsInput SetupEngine Engine Oil Temperature This sensor should use Analog Input Channels 7 -12 as these have configurable pull-up resistors. Filter Settings FIlter Setting Minimum = 0 (OFF) FIlter Setting Maximum = 50 Recommended Filter Range = 35 - 40