ALL data/parameters transmitted from the ECU over CAN have units defined by the corresponding parameter calibration table(s). This can be setup and adjusted through the PC tuning software Emtune.

  1. All Data is unsigned
  2. All Data is 16 bits
  3. Low byte of each word (16bit) is transmitted first.

Examples:

  • Temperature in degrees Celsius or Fahrenheit
  • Pressure in kPa,  PSI,  InHg
  • Speed in Kph, mph, m/s


    • Speed in Kph, mph, m/s

Type

Units

Min Value

Max Value

Conversion Raw to Displayed Value

Position

%Posn

-100.0 %

100.0 %

Display = ECU value  x  0.1 - 100

                  OR

ECU value A:   0000 becomes  -100.0  %   

ECU value B:   2000 becomes  100.0 %

Pressure

kPa/PSI

0.0 

6500.0 

Display = ECU value x  0.1 

                  OR

ECU value A: 0  becomes  0.0  kPa/PSI   

ECU value B: 1000 becomes  100.0  kPa/PSI 

Temperature

oC / oF   

-50.0 

250.0 

Display = ECU value x  0.1  - 50

                  OR

ECU value A: 0  becomes  -50.0 oC/   oF

ECU value B: 1500 becomes  100.0 oC  / oF

 

Lambda

La

0.000

  2.000


Display = ECU value x  0.001

                  OR

ECU value A    0  becomes  0.000 La    

ECU value B    1000  becomes  1.000 La



Type

Units

Min Value

Max Value

Conversion Raw to Displayed Value

Speed

Kph/mph

0.0 

6500.0

Display = ECU value x  0.1 

                  OR

ECU value A    0     becomes  0.0  kph   

ECU value B    1000     becomes  100.0  kph

Ignition Angle

oBTDC

-100.0 oBTDC

  100.0 oBTDC

Display = ECU value x  0.1 - 100

                  OR

ECU value A 1000 becomes  0.0 oBTDC    

ECU value B 2000 becomes  100.0 oBTDC  



Voltage

V

0.000

  20.000


Display = ECU value x  0.001

                  OR

ECU value A    0  becomes  0.000V    

ECU value B    20000  becomes  20.000V  



Percentage1

%

0.0

  100.0


Display = ECU value x  0.1

                  OR

ECU value A    0  becomes  0.0%    

ECU value B    1000  becomes  100.0%  



Percentage2

%

-100.00

  100.00


Display = ECU value x  0.01 - 100

                  OR

ECU value A    0  becomes  -100.00%    

ECU value B    10000  becomes  0.00%  

ECU value C    20000  becomes  +100.00%  



Type

Units

Min Value

Max Value

Conversion Raw to Displayed Value

Rate of Change1

%/sec

-100.0 

+ 100.0

Display = ECU value x  0.1 - 100

                  OR

ECU value A    0     becomes  -100.0 %/sec   

ECU value B    1000     becomes  0.0 %/sec

Or 

ECU value B    2000   becomes  +100.0 %/sec


Rate of Change2

rpm/sec

-20000 

20000

Display = ECU value x   - 20000

                  OR

ECU value A    0     becomes  - 20000 rpm/sec   

ECU value B    20000 becomes  0 rpm /sec

Or 

ECU value B    40000   becomes +  20000 %/sec


G-Force

G

-10.00 G

  10.00 G

Display = ECU value x  0.01 - 10

                  OR

ECU value A 0 becomes  -10.00 G    

ECU value B 1000 becomes  0.00 G

 or

ECU value B 2000 becomes  10.00 G


RPM

RPM

0

300000

Display = ECU value x  1 

                  OR

ECU value A 0 becomes  0 RPM   

ECU value B 20000 becomes  20000 RPM


Pressure Diff

kPa/PSI

0.0 

6500.0 

Display = ECU value x  0.1 - 1000

                  OR

ECU value A: 10000  becomes  0.0  kPa/PSI   

ECU value B: 8000 becomes  - 200.0  kPa/PSI 


Counter


0 

65535

Display = ECU value 

                  OR

ECU value A    0     becomes   0   

ECU value B    10     becomes  10


VVT Position

Deg

-100.0

+100.0

Display = ECU value x  0.1 - 200

                  OR

ECU value A: 2000  becomes  0.0  Deg   

ECU value B: 2304 becomes  30.4 Deg (Cam Advanced)

ECU value 3: 1871 becomes  -12.9. Deg (Cam Retarded)