For details : 


Emtron Lambda CAN Manual



Click the link below to download or visit emtron.world/download


Click here to download



Reset CAN IDs to Default


0: OFF

1: ON

 

This will reset the ELC CAN IDs back to their default values

 

Channel 1 = 671, Channel 2 = 672


Set back to zero when finished.


Enable Heater Override 


0: OFF

1: ON

 

When enabled, the ECU controls when the Lambda heater is ON or OFF. This is done through  the "ELC HEater RPM Lockout" and "ELC Heater Post Start Lockout: settings. 


When disable the ELC controls the heater(s) which will turn On 15 secs after the device power up.


Enable EMAP 


0: OFF

1: ON

 

When enabled, the ECU will send EMAP data to the ELC. This units should be in kPa


** When enabled please make sure the EMAP is configured correctly inside the ECU.


ELC Heater RPM Lockout 


RPM Below which heater will be locked out


ELC Heater Post Start Lockout 


Timer before which heater will turned on Post Start up


ELC Lambda 1 Test Enable 


Forces the ELC to send this Test Value over the CAN bus.


Allows the user to confirm the ECU calibration is setup correctly.


0 = OFF


ELC Lambda 2 Test Enable 


Forces the ELC to send this Test Value over the CAN bus.


Allows the user to confirm the ECU calibration is setup correctly.


0 = OFF