Time to 100% full the ECU logging Memory =                ( Memory Size (MB)  / 2 )             

                                               Logging Rate x Number of Parameter 


NOTE: When the logging mode is set to "Circular" this is the time to complete one logging cycle


Example1 : Dataset 1 Logging Rate = 100Hz. Logging 20 parameters. Memory Size at 4MB



Time for ECU logging memory to reach 100% capacity =        4MB /2          = 1000 secs = 16.6 minutes

                                                          100 x 20


Example2 : Dataset 1 Logging Rate = 100Hz. Logging 20 parameters. Dataset 2 Logging Rate = 5Hz. Logging 20 parametersMemory Size at 4MB



Time for ECU logging memory to reach 100% capacity =              4MB /2                         = 952 secs = 15.87 minutes

                                                          (100 x 20) + (5 x 20)


Example3 : Dataset 1 Logging Rate = 100Hz. Logging 50 parameters. Memory Size at 32MB



Time for ECU logging memory to reach 100% capacity =        32MB /2          = 3200 secs = 53.3 minutes

                                                          100 x 50