Bandwidth Considerations
Bus bandwidth needs to be considered when data is transmitted over CAN. The ECU has Transmit rates from 10Hz up to 1000Hz.
Example 1:
The following uses the Predefined 1 Tx DATA set. This uses 10 sequential addresses and it total transmits the value of 40 parameters. CAN Baud rate at 1Mbps
|
Tx Rate |
Number of Messages |
Bandwidth Used (%) |
Available Bandwidth for other devices |
|
10Hz |
10 |
1.2% |
98.8% |
|
50Hz |
10 |
6.1% |
93.9% |
|
100Hz |
10 |
12.2% |
87.8% |
|
500Hz |
10 |
61% |
39% |
|
1000Hz |
10 |
Cannot be achieved |
|
Example 2:
The following uses the Custom 1 Tx DATA set. This uses 5 sequential addresses and it total transmits the value of 20 parameters. CAN Baud rate at 1Mbps
|
Tx Rate |
Number of Messages |
Bandwidth Used (%) |
Available Bandwidth for other devices |
|
10Hz |
5 |
0.6% |
99.4% |
|
50Hz |
5 |
3.05% |
96.95% |
|
100Hz |
5 |
6.1% |
93.9% |
|
500Hz |
5 |
30.5% |
69.5% |
|
1000Hz |
5 |
61% |
39% |